YinkeValve · Engineered Flow Controlsale@yinkevalves.com
Home / Products / LCC Tilting Disc Check Valve Class 600
Check Valve

LCC Tilting Disc Check Valve Class 600

LCC Tilting Disc Check Valve Class 600 combines Tilting Disc Check Valve, LCC, Class 600, Flanged and Metal Seat in one defined purchasing configuration. Use it when those core parameters are already fixed by the valve list or piping specification.

API 594 / ASME B16.34Design basis
Class 600Pressure class
LCCPressure-boundary material
Technical Configuration

LCC Tilting Disc Check Valve Class 600

DesignTilting Disc Check Valve
StandardAPI 594 / ASME B16.34
Pressure ClassClass 600
Body MaterialLCC
End ConnectionFlanged
Seat / SealMetal Seat
Service / Application
OperationSelf-Acting
Buyer Decision Summary

Why This Exact Configuration Exists

The commercial scope for LCC Tilting Disc Check Valve Class 600 is controlled by the interaction of body construction, material, pressure class, piping interface, sealing and operation—not by the valve name alone.

Selection reason

Choose LCC Tilting Disc Check Valve Class 600 when the RFQ specifically calls for Tilting Disc Check Valve, LCC, Class 600 and Flanged. Reverse-flow performance is governed by closure travel, spring/hinge dynamics, orientation and system velocity.

What changes technically

For LCC Tilting Disc Check Valve Class 600, the combined technical effect is low-temperature cast carbon steel where minimum design temperature and impact properties matter; higher-pressure service where pressure-boundary dimensions, bolting and operating loads become more significant; and the flange standard, facing, drilling, gasket and face-to-face dimensions must align with the mating piping. Metal seating shifts the design toward hardfacing/coating, lapping, higher torque and wear control rather than polymer-seat compliance.

What to confirm before quote

Before pricing LCC Tilting Disc Check Valve Class 600, confirm nominal size and bore, design pressure/temperature, trim and stem/shaft material, the Metal Seat sealing requirement, Self-Acting operating basis, leakage/test acceptance and the final drawing/document package.

Compared with a nearby configuration

Compared with LCC Tilting Disc Check Valve Class 150, this configuration changes pressure class (Class 600 instead of Class 150). That difference is what a buyer should verify before treating the two pages as commercially interchangeable.

Design Basis

In LCC Tilting Disc Check Valve Class 600, the Tilting Disc Check Valve construction determines the closure support, body arrangement and maintenance approach. Confirm bore or flow path, body joint, stem/shaft retention, seat support, anti-blowout features where applicable and access requirements against the approved GA.

Pressure-Boundary Material

For LCC Tilting Disc Check Valve Class 600, the pressure boundary is LCC. Low-temperature cast carbon steel where minimum design temperature and impact properties matter. Because this valve is Class 600 with Flanged, verify the material condition, trim compatibility, bolting and any PMI/NDE or corrosion-control requirement as one package.

Pressure Class and Piping Interface

For LCC Tilting Disc Check Valve Class 600, the specified rating is Class 600 and the piping interface is Flanged. Higher-pressure service where pressure-boundary dimensions, bolting and operating loads become more significant. The flange standard, facing, drilling, gasket and face-to-face dimensions must align with the mating piping. Final dimensions and pressure-temperature suitability must therefore be checked against the selected material and design temperature, not inferred from class alone.

Seat and Seal Arrangement

For LCC Tilting Disc Check Valve Class 600, the listed sealing basis is Metal Seat. Metal seating shifts the design toward hardfacing/coating, lapping, higher torque and wear control rather than polymer-seat compliance. Confirm leakage acceptance, pressure/temperature limits and cycling together with the Class 600 loading and the selected Self-Acting operating method.

Operation and Actuation

For LCC Tilting Disc Check Valve Class 600, operation is Self-Acting. Self-acting operation depends on process differential pressure and closure dynamics rather than an external operator. The final operator or actuator basis should use the actual size, maximum differential pressure, Metal Seat friction/seating behavior and required operating or emergency time.

Service Conditions

No service qualifier is fixed by the product name, so LCC Tilting Disc Check Valve Class 600 should be released only after the actual fluid, temperature range, pressure cases, cycling and special service requirements are known.

Inspection and Testing

For LCC Tilting Disc Check Valve Class 600, tie MTC/heat traceability, dimensional inspection, PMI/NDE where specified, shell/seat testing, coating checks, witness points and final records to the approved API 594 / ASME B16.34 datasheet and ITP.

Documents Before Release

The manufacturing release for LCC Tilting Disc Check Valve Class 600 should reference the approved GA, material/trim schedule, seat/seal definition, operator or actuator data, test scope and required final documentation.

Relevant Product Ranges

Ready to Review LCC Tilting Disc Check Valve Class 600?

Send the project specification for LCC Tilting Disc Check Valve Class 600; the quotation can then confirm size-dependent dimensions, trim, sealing, operation, inspection and final documents without changing the defined LCC / Class 600 basis.

Request Technical Quote