YinkeValve · Engineered Flow Controlsale@yinkevalves.com
Home / Products / WCB Tilting Disc Check Valve Class 900
Check Valve

WCB Tilting Disc Check Valve Class 900

WCB Tilting Disc Check Valve Class 900 combines Tilting Disc Check Valve, WCB, Class 900, Flanged and Metal Seat in one defined purchasing configuration. Use it when those core parameters are already fixed by the valve list or piping specification.

API 594 / ASME B16.34Design basis
Class 900Pressure class
WCBPressure-boundary material
Technical Configuration

WCB Tilting Disc Check Valve Class 900

DesignTilting Disc Check Valve
StandardAPI 594 / ASME B16.34
Pressure ClassClass 900
Body MaterialWCB
End ConnectionFlanged
Seat / SealMetal Seat
Service / Application
OperationSelf-Acting
Buyer Decision Summary

Why This Exact Configuration Exists

The commercial scope for WCB Tilting Disc Check Valve Class 900 is controlled by the interaction of body construction, material, pressure class, piping interface, sealing and operation—not by the valve name alone.

Selection reason

Choose WCB Tilting Disc Check Valve Class 900 when the RFQ specifically calls for Tilting Disc Check Valve, WCB, Class 900 and Flanged. Reverse-flow performance is governed by closure travel, spring/hinge dynamics, orientation and system velocity.

What changes technically

For WCB Tilting Disc Check Valve Class 900, the combined technical effect is cast carbon steel for general hydrocarbon and process pressure boundaries; high-pressure service where end preparation, wall section and operating loads need tighter coordination; and the flange standard, facing, drilling, gasket and face-to-face dimensions must align with the mating piping. Metal seating shifts the design toward hardfacing/coating, lapping, higher torque and wear control rather than polymer-seat compliance.

What to confirm before quote

Before pricing WCB Tilting Disc Check Valve Class 900, confirm nominal size and bore, design pressure/temperature, trim and stem/shaft material, the Metal Seat sealing requirement, Self-Acting operating basis, leakage/test acceptance and the final drawing/document package.

Compared with a nearby configuration

Compared with WCB Tilting Disc Check Valve Class 150, this configuration changes pressure class (Class 900 instead of Class 150). That difference is what a buyer should verify before treating the two pages as commercially interchangeable.

Design Basis

In WCB Tilting Disc Check Valve Class 900, the Tilting Disc Check Valve construction determines the closure support, body arrangement and maintenance approach. Confirm bore or flow path, body joint, stem/shaft retention, seat support, anti-blowout features where applicable and access requirements against the approved GA.

Pressure-Boundary Material

For WCB Tilting Disc Check Valve Class 900, the pressure boundary is WCB. Cast carbon steel for general hydrocarbon and process pressure boundaries. Because this valve is Class 900 with Flanged, verify the material condition, trim compatibility, bolting and any PMI/NDE or corrosion-control requirement as one package.

Pressure Class and Piping Interface

For WCB Tilting Disc Check Valve Class 900, the specified rating is Class 900 and the piping interface is Flanged. High-pressure service where end preparation, wall section and operating loads need tighter coordination. The flange standard, facing, drilling, gasket and face-to-face dimensions must align with the mating piping. Final dimensions and pressure-temperature suitability must therefore be checked against the selected material and design temperature, not inferred from class alone.

Seat and Seal Arrangement

For WCB Tilting Disc Check Valve Class 900, the listed sealing basis is Metal Seat. Metal seating shifts the design toward hardfacing/coating, lapping, higher torque and wear control rather than polymer-seat compliance. Confirm leakage acceptance, pressure/temperature limits and cycling together with the Class 900 loading and the selected Self-Acting operating method.

Operation and Actuation

For WCB Tilting Disc Check Valve Class 900, operation is Self-Acting. Self-acting operation depends on process differential pressure and closure dynamics rather than an external operator. The final operator or actuator basis should use the actual size, maximum differential pressure, Metal Seat friction/seating behavior and required operating or emergency time.

Service Conditions

No service qualifier is fixed by the product name, so WCB Tilting Disc Check Valve Class 900 should be released only after the actual fluid, temperature range, pressure cases, cycling and special service requirements are known.

Inspection and Testing

For WCB Tilting Disc Check Valve Class 900, tie MTC/heat traceability, dimensional inspection, PMI/NDE where specified, shell/seat testing, coating checks, witness points and final records to the approved API 594 / ASME B16.34 datasheet and ITP.

Documents Before Release

The manufacturing release for WCB Tilting Disc Check Valve Class 900 should reference the approved GA, material/trim schedule, seat/seal definition, operator or actuator data, test scope and required final documentation.

Relevant Product Ranges

Ready to Review WCB Tilting Disc Check Valve Class 900?

Send the project specification for WCB Tilting Disc Check Valve Class 900; the quotation can then confirm size-dependent dimensions, trim, sealing, operation, inspection and final documents without changing the defined WCB / Class 900 basis.

Request Technical Quote